ÐÂÔÂÖ±²¥appÏÂÔØ

Phishing warning 01-May-2024
We are aware of phishing emails targeting speakers of events whose names appear on our events pages. If you are unsure if an email regarding event registration or accommodation has come from us please contact us and do not provide any credit card details or personal information

5-day Comprehensive GC-MS Training (Agilent SQ MS with MassHunter)

1 October 2018 09:00 - 5 October 2018 17:00, Milton Keynes, United Kingdom


Introduction

What will you learn on this course?

The five-day Comprehensive GC-MS Training course introduces the fundamental theory of quadrupole GC-MS along with the operation, maintenance and troubleshooting of the Agilent single quadrupole Mass Spectrometer using MassHunter software.

This course includes an introduction to quadrupole mass spectrometry; hardware configuration; MS tuning; data acquisition in scan and selected ion monitoring (SIM) modes; qualitative & quantitative data analysis; reports; sequencing; and an introduction to deconvolution and retention time locking.

The course will train the operator to perform the maintenance required to ensure the smooth running of the instrument. The course also discusses the principles of troubleshooting by examining the effects of faults in the system on the chromatographic output. This course includes an introduction to troubleshooting and maintenance focusing on tunes & diagnostics, GC considerations, vacuum system, ion source, quadrupole mass filter and MS detector.

It combines a mixture of classroom based presentations with hands-on software and hardware lab exercises, to give you comprehensive training.

You can attend all 5 days of the course for a complete training solution. Alternatively you can attend the 2-day Comprehensive GC-MS Hardware (Agilent SQ MS) course or 3-day Comprehensive GC-MS Software Training (MassHunter) course for specific training on hardware or software.

Learning Outcomes

You will learn the theory & principles of mass spectrometry focusing on the quadrupole GC-MS
You will become familiar with the Agilent single quadrupole Mass Spectrometer instrumentation learning about the function & operation of individual components
You will gain experience of adjusting the important MS parameters
You will gain practical experience of performing maintenance of each MS component including vacuum system, ion source, quadrupole mass filter & detector
You will learn the strategies and gain practical experience of instrument troubleshooting
You will learn the operation of the MassHunter software
You will learn installation, set-up and get an overview of the software
You will learn about the types of tuning methods, undertake air/water checks & an autotune then interpret the results
You will learn how to create a full scan and SIM method to gain an understanding of each method type
You will analyse individual samples and create sequences for analysing multiple samples
You will undertake qualitative data analysis including library searching and deconvolution
You will undertake quantitative data analysis creating calibration curves and producing appropriate sample reports
You will have an introduction to deconvolution and learn retention time locking

Who is this course for?

This course is primarily for analysts and technicians responsible for the operation, maintenance and troubleshooting of Agilent quadrupole GC-MS instruments with MassHunter software. This is also the introductory course for those learning the Agilent triple quadrupole mass spectrometer with MassHunter software. Please note that while hands on training will take place on an Agilent 5975 or 5973 the course is suitable for all models of Agilent single quadrupole MSD.

Course Venue: The Open University, Milton Keynes, UK | arrange this course onsite
Number of days: 5
Price: Â£1520 + VAT
 

Venue
The Open University

The Open University, Walton Hall, Milton Keynes, MK7 6AA, United Kingdom

Useful links

Organised by

Anthias Consulting Ltd are experts in the separation sciences in the fields of Gas Chromatography (GC), Mass Spectrometry (GC-MS) and related techniques.


Contact information
Search
 
 
Showing all upcoming events
Start Date
End Date
Location
Subject area
Event type

Advertisement
Spotlight


E-mail Enquiry
*
*
*
*